Patch-ID# 103171-01 Keywords: Solstice Enterprise Manager 1.1 Synopsis: Solstice Enterprise Manager 1.1: patch Date: Jan/22/96 Solaris Release: 2.4 SunOS Release: 5.4 Unbundled Product: Solstice Enterprise Manager Unbundled Release: 1.1 Relevant Architectures: sparc BugId's fixed with this patch: 1230623 Changes incorporated in this version: 1230623 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: SUNWemmis: SUNWconn/em/bin/em_mis Problem Description: 1230623 The MIS times out, after one minute, an M-Get Request that has been forwarded to the CMIP MPA. Patch Installation Instructions: -------------------------------- Refer to the Install.info file for instructions on using the generic 'installpatch' and 'backoutpatch' scripts provided with each patch. Any other special or non-generic installation instructions should be described below as special instructions. Special Install Instructions: ----------------------------- The MIS to MPA Request and Association timers are now read from the EM-config file. To change the default timeouts of 60 and 300 seconds respectively, the following lines: EM_MIS_TO_MPA_REQ_TIMEOUT: EM_MIS_TO_MPA_ASSOC_TIMEOUT: should be added to the ./SUNWconn/em/build/acct/EM-config file and, as root, em_services -r executed. e.g. EM_MIS_TO_MPA_REQ_TIMEOUT: 300 EM_MIS_TO_MPA_ASSOC_TIMEOUT: 600 sets the Request Timeout to 5 minutes, and the Association Idle Timeout to 10 minutes.